Polyaluminum chloride coagulation in drinking water treatment

Dissolved organic matter, DOC [mg C/L], is a representative parameter for the content of organic matter in natural waters. Along the A254 absorbance as a measure of organic compounds determined at X = 254nm UV [cm'1], DOC underlies the calculation of SUVA (Specific Ultraviolet Absorbance) = A25...

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerző: Masu Smaranda
Testületi szerző: International Symposium on Analytical and Environmental Problems (17.) (2011) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: SZAB Szeged 2012
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 17
Kulcsszavak:Víztisztítás
Tárgyszavak:
Online Access:http://acta.bibl.u-szeged.hu/76459
LEADER 02097naa a2200241 i 4500
001 acta76459
005 20220822102333.0
008 220810s2012 hu o 1|| eng d
020 |a 978-963-315-066-5 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a eng 
100 1 |a Masu Smaranda 
245 1 0 |a Polyaluminum chloride coagulation in drinking water treatment  |h [elektronikus dokumentum] /  |c  Masu Smaranda 
260 |a SZAB  |b Szeged  |c 2012 
300 |a 343-346 
490 0 |a Proceedings of the International Symposium on Analytical and Environmental Problems  |v 17 
520 3 |a Dissolved organic matter, DOC [mg C/L], is a representative parameter for the content of organic matter in natural waters. Along the A254 absorbance as a measure of organic compounds determined at X = 254nm UV [cm'1], DOC underlies the calculation of SUVA (Specific Ultraviolet Absorbance) = A254/DOC x 100 [L-m '-mg'1]. SUVA can be used to describe the composition of the water in terms of hydrophobic / hydrophilic character. The study results are presented in the coagulation process with pre-hydrolyzed aluminum salt, as a polyaluminum chloride (PAC1), a simple salt of Al, as an A1 sulfate (Alum), applied to surface water intended for drinking water. From SUVA values DOC removal efficiency in the coagulation process is estimated. SUVA = 2-4 estimated efficiencies of 25-50% removal in DOC. When using PAC1, DOC removal efficiency is within the range of 27-53%, and slightly lower when using Alum. SUVA values <2 indicate DOC removal efficiencies <25%. DOC removal efficiencies obtained from the use of Alum are within the range 5.6-8.4% and those obtained when used as coagulation agent PAC1 are in the range 20.8-23.8%. 
650 4 |a Természettudományok 
650 4 |a Kémiai tudományok 
650 4 |a Biológiai tudományok 
695 |a Víztisztítás 
711 |a International Symposium on Analytical and Environmental Problems (17.) (2011) (Szeged)  |c Szeged  |d 2011. szeptember 19. 
856 4 0 |u http://acta.bibl.u-szeged.hu/76459/1/proceedings_of_isaep_2011_343-346.pdf  |z Dokumentum-elérés