Single-shot CEP drift measurement at arbitrary repetition rate based on dispersive Fourier transform
This paper presents a single-shot technique for measuring CEP. The Temporal dispersion based One-shot Ultrafast Carrier envelope phase Analysis method (TOUCAN) is an arbitrary repetition rate single-shot CEP drift measurement technique based on dispersive Fourier transformations and has been experim...
Elmentve itt :
| Szerzők: | |
|---|---|
| Dokumentumtípus: | Cikk |
| Megjelent: |
2019
|
| Sorozat: | OPTICS EXPRESS
27 No. 9 |
| Tárgyszavak: | |
| doi: | 10.1364/OE.27.013387 |
| mtmt: | 31094709 |
| Online Access: | http://publicatio.bibl.u-szeged.hu/26981 |
| Tartalmi kivonat: | This paper presents a single-shot technique for measuring CEP. The Temporal dispersion based One-shot Ultrafast Carrier envelope phase Analysis method (TOUCAN) is an arbitrary repetition rate single-shot CEP drift measurement technique based on dispersive Fourier transformations and has been experimentally tested at 100 kHz. TOUCAN was validated by a direct comparison of decimated data with an independent traditional CEP drift measurement technique. The impact of a temporal jitter on the CEP drift measurement is investigated and a new mitigation technique is shown to produce high accuracy jitter-free CEP drift extraction. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement |
|---|---|
| Terjedelem/Fizikai jellemzők: | 13387-13399 |
| ISSN: | 1094-4087 |